Salemkar Industrial Concrete Co.

PHONE

(098)2833482190

EMAIL

info@salemkar.co.ir

OPENING TIME

Sat - Thu 8:00 - 16:00
Price Request

Precast Concrete Wall

In order to accelerate spatial operations, reduce costs, and improve the safety and mental comfort, double-sided precast walls are designed and produced in this complex in various forms and sizes along with a Pier and a column with the possibility of installation at the order place. They are currently being installed and used in Shahid Rajaee Power Plants, Tehran Municipality Water and Sewage Co., and the universities of the country.

Panel spec table
Row Length (cm) Height (cm) Thickness (cm) Wall design Mesh weight (kg) Piece weight (kg)
1 400 180 12 Malon 3/26 1093
2 400 125 12 Malon 6/31 1620
Product dimensions

of production columns are different in 2 sizes. The following table shows the specifications of precast columns along with their dimensions.

Column spec table
Row Height (cm) Length
(cm)
Width (cm) Mesh weight (kg) Piece weight (kg)
1 285 30 25 13 392
2 285 40 30 7/18 650
Row 2 is a column with two corners.

Product dimensions
of production Piers are different in 2 sizes. The following table shows the specifications of precast Piers along with their dimensions.

Pier spec table
Row Height (cm) Length
(cm)
Width (cm) Mesh weight (kg) Piece weight (kg)
1 55 90 73 7/1 540
2 55 110 73 5/3 650
Technical specifications of the rebars used in the product of wall, column and Pier

In the production of the wall set product, ribbed rebars No. 8, 10 and 14 are used. In the following, some technical specifications and chemical elements in the used rebars are mentioned.
Grade: AJ400A3
Production method: hot rolling yield
stress: 430 MPa
Tensile strength: 647-655 MPa
Increase in length: 25%

Table of chemical elements (weight percentage):
C Si Mn P S CE
0.317-0.33 0.21-0.29 0.75-0.776 0.011-0.019 0.012-0.026 0.45-0.46

The compressive strength of concrete used in the product of wall, column and Pier is the
characteristic strength of concrete used in the precast wall set is equal to 25 MPa.